Five uses, five different problems — and most often the same starting point: replacing a lead-acid battery with lithium. The same cells do not go everywhere, and what survives on a zem will not do in a plant room.
12 / 24 / 48 V
Solar and inverters
On the ground
A lead battery rarely delivers what was expected of it on a solar kit. It dislikes deep daily discharge, it loses a lot to heat, and one failed cell takes the whole bank with it. Every installer knows what follows: a replacement far sooner than planned, and a customer who starts doubting solar altogether.
What we advise
A lithium solar battery changes the arithmetic. An LFP pack accepts being taken to 80 % depth every day, which changes the sizing: you install less capacity for the same usable energy. The BMS watches every cell and cuts out before damage, instead of letting the bank degrade quietly.
Cells that suit
-
LFP prismatic 280 Ah LFP
- Nominal voltage
- 3.2 V
- Capacity
- 280 Ah
-
LFP prismatic 100 Ah LFP
- Nominal voltage
- 3.2 V
- Capacity
- 100 Ah
-
32700 LFP LFP
- Nominal voltage
- 3.2 V
- Capacity
- 6,000 mAh
60 / 72 V
Electric motorcycles and three-wheelers
On the ground
A zem runs all day, starts under load and often uphill, and charges between fares. Lead is too heavy for that, takes current surges badly, and the space under the seat is counted in centimetres.
What we advise
Cylindrical NMC, which stores more energy in the same volume and takes high currents. The BMS is sized on the start-up peak, not on average current: a BMS that cuts out on a hill makes the bike useless. Cell holders chosen to take the vibration.
Cells that suit
-
21700 NMC · high drain NMC
- Nominal voltage
- 3.6 V
- Capacity
- 4,000 mAh
-
21700 NMC · high energy NMC
- Nominal voltage
- 3.6 V
- Capacity
- 5,000 mAh
-
32140 LFP LFP
- Nominal voltage
- 3.2 V
- Capacity
- 15,000 mAh
12 / 24 / 48 V
Telecom and UPS
On the ground
The pack sleeps most of the time and has to answer the second the grid drops. In a plant room that heats up, lead ages even when it is not working — and you only find out when you need it.
What we advise
LFP, for heat tolerance and because it copes with sitting charged for long stretches. Format chosen to fit the rack you already have, and a BMS with comms if your equipment can read them.
Cells that suit
-
LFP prismatic 100 Ah LFP
- Nominal voltage
- 3.2 V
- Capacity
- 100 Ah
-
LFP prismatic 50 Ah LFP
- Nominal voltage
- 3.2 V
- Capacity
- 50 Ah
-
18650 LFP LFP
- Nominal voltage
- 3.2 V
- Capacity
- 1,500 mAh
12 / 24 V
Street lighting
On the ground
One cycle a night, all year, outdoors, with nobody watching. It is the hardest profile for a lead battery: daily cycling, heat, and a failure you only notice once the lamp stays dark.
What we advise
LFP, for the cycles and the temperature. The enclosure is chosen as much on exposure as on the dimensions of the pack: a box in full sun all day imposes constraints a plant room does not.
Cells that suit
-
32700 LFP LFP
- Nominal voltage
- 3.2 V
- Capacity
- 6,000 mAh
-
26650 LFP LFP
- Nominal voltage
- 3.2 V
- Capacity
- 3,400 mAh
-
LFP prismatic 50 Ah LFP
- Nominal voltage
- 3.2 V
- Capacity
- 50 Ah
To specification
Power tools
On the ground
The original pack is dead, the tool is still good, and the manufacturer replacement often costs more than the tool itself — when it is still available at all.
What we advise
A new pack in the footprint of the original housing, with the connector and charging contact the tool imposes. High-drain cells, because a tool pulls hard and briefly.
Cells that suit
-
18650 NMC · high drain NMC
- Nominal voltage
- 3.6 V
- Capacity
- 2,500 mAh
-
21700 NMC · high drain NMC
- Nominal voltage
- 3.6 V
- Capacity
- 4,000 mAh
-
18650 NMC · high energy NMC
- Nominal voltage
- 3.6 V
- Capacity
- 3,500 mAh
Quote
Your use is not on the list?
Describe it. Most of the requests that reach us are combinations of the above.
No prices online: every requirement differs, so every quote is priced on its own.