The lithium cells

Two families, two ways to build a pack. The choice is not made on the datasheet but on what you are building: the space, the current, the number of cycles you expect.

Type

Format

Chemistry

Capacity

Use

  • 18650 NMC · high energy NMC
    Nominal voltage
    3.6 V
    Capacity
    3,500 mAh
    Continuous discharge
    10 A

    The most common format, in the version that favours capacity. Choose it when the pack has to be compact and the current drawn stays moderate.

    See the detail

  • 18650 NMC · high drain NMC
    Nominal voltage
    3.6 V
    Capacity
    2,500 mAh
    Continuous discharge
    20 A

    Less capacity, much more current. This is the cell for tool packs and small traction packs, where the start-up peak matters more than range.

    See the detail

  • 18650 LFP LFP
    Nominal voltage
    3.2 V
    Capacity
    1,500 mAh
    Continuous discharge
    5 A

    Little capacity for the volume, but four times the cycle life of an NMC and far better heat tolerance. For small packs that must last unattended.

    See the detail

  • 21700 NMC · high energy NMC
    Nominal voltage
    3.6 V
    Capacity
    5,000 mAh
    Continuous discharge
    15 A

    The best energy-to-volume ratio among our cylindrical cells. Fewer cells for the same energy, so fewer welds and fewer points of failure.

    See the detail

  • 21700 NMC · high drain NMC
    Nominal voltage
    3.6 V
    Capacity
    4,000 mAh
    Continuous discharge
    35 A

    The cell for demanding zem packs: 35 A continuous per cell, enough to take loaded hill starts.

    See the detail

  • 26650 LFP LFP
    Nominal voltage
    3.2 V
    Capacity
    3,400 mAh
    Continuous discharge
    10 A

    A good compromise for small solar systems: enough capacity to keep the cell count down, enough cycles for daily use.

    See the detail

  • 32700 LFP LFP
    Nominal voltage
    3.2 V
    Capacity
    6,000 mAh
    Continuous discharge
    18 A

    The most requested format for a 12 or 24 V pack built from cylindrical cells. Four cells in series give 12.8 V nominal.

    See the detail

  • 32140 LFP LFP
    Nominal voltage
    3.2 V
    Capacity
    15,000 mAh
    Continuous discharge
    45 A

    The largest cylindrical cell in the catalogue. A lot of energy per cell and few connections to make, for traction packs that pull hard.

    See the detail

  • LFP prismatic 50 Ah LFP
    Nominal voltage
    3.2 V
    Capacity
    50 Ah
    Continuous discharge
    50 A

    The smallest prismatic cell we carry. For a compact 12 or 24 V pack, or a telecom rack where space is tight.

    See the detail

  • LFP prismatic 100 Ah LFP
    Nominal voltage
    3.2 V
    Capacity
    100 Ah
    Continuous discharge
    100 A

    The entry format for home solar storage. Sixteen cells in series give a 48 V pack of about 5.1 kWh.

    See the detail

  • LFP prismatic 230 Ah LFP
    Nominal voltage
    3.2 V
    Capacity
    230 Ah
    Continuous discharge
    230 A

    A useful middle ground when the 280 Ah will not fit the cabinet you have. Sixteen in series give about 11.8 kWh at 48 V.

    See the detail

  • LFP prismatic 280 Ah LFP
    Nominal voltage
    3.2 V
    Capacity
    280 Ah
    Continuous discharge
    280 A

    The most requested format for 48 V solar storage. Sixteen cells in series give about 14.3 kWh.

    See the detail

  • LFP prismatic 314 Ah LFP
    Nominal voltage
    3.2 V
    Capacity
    314 Ah
    Continuous discharge
    314 A

    The same footprint as the 280 Ah, with more capacity. Worth preferring on a new project, when the cabinet is not already fixed.

    See the detail

Typical manufacturer figures for the format and chemistry. The figures for the batch in stock come with your quote.

Compare

Cylindrical or prismatic

The table below settles most cases. If yours is not in it, describe it to us.

Criterion Cylindrical LFP prismatic
Capacity per cell 2 to 15 Ah 50 to 320 Ah
Chemistries NMC and LFP LFP only
Assembly Spot welding, hundreds of welds Bolted busbars, a few dozen
Where it fits Traction, power tools, small systems 12 to 48 V solar storage
Footprint Fits around awkward shapes Regular blocks, stacked

Choosing

Which format, which chemistry

  • NMC or LFP

    NMC stores more energy in the same volume and takes high currents. LFP lasts more cycles and copes better with heat. For a solar pack that works every day, take LFP. For a compact traction pack, NMC.

  • The format

    The bigger the cell, the fewer welds and connections to make, so the fewer points of failure. In exchange, a big cell sheds its heat more slowly. The 21700 is the most common compromise on traction packs today.

  • The grades

    The same reference exists in several capacity and current grades. The grade changes real capacity, allowable current and the spread between cells. We give you the grade of the batch in stock with the quote, not before: it depends on the shipment.

  • Cell matching

    In a pack, the weakest cell sets the capacity of the whole. We match cells from the same batch before assembly, and that is what separates a pack that holds its promises from one that drifts within months.

Sizing

Building a prismatic pack

  • How many cells in series

    LFP is 3.2 V nominal. A 12 V pack is 4 cells in series (4S, 12.8 V), a 24 V pack is 8S (25.6 V), a 48 V pack is 16S (51.2 V). Your inverter voltage sets that number, not the capacity you are after.

  • Working out the energy

    Multiply the pack nominal voltage by the capacity of one cell. Sixteen 280 Ah cells in series give 51.2 V × 280 Ah, about 14.3 kWh. For more energy, add a pack in parallel rather than lengthening the series.

  • Busbars and hardware

    Supplied with the cells. The tightening torque is given by the manufacturer and it matters: too tight and the terminal thread is ruined, so is the cell; too loose and the joint heats up under load.

  • Matching and balancing

    The cells of one pack must come from the same batch and start at the same voltage. The BMS then balances them over the cycles, but it corrects a slow drift, not a gap built in at assembly.

Quote

Tell us what you are building

If you are torn between the two families, describe the installation rather than the cell: we will tell you which one holds.

No prices online: every requirement differs, so every quote is priced on its own.