The same pack, five times
Take a fixed need — 5 kWh gross — and build it with each format in the catalogue, at typical manufacturer values. The weld count is a theoretical minimum: two per cell, one at each pole. In practice a serious cylindrical pack carries more, because links are doubled on the branches that carry current.
- 18650 high-energy NMC, 12.6 Wh per cell: 397 cells, 19.1 kg, 794 welds.
- 21700 high-energy NMC, 18 Wh: 278 cells, 19.5 kg, 556 welds.
- 32700 LFP, 19.2 Wh: 261 cells, 37.8 kg, 522 welds.
- 32140 LFP, 48 Wh: 105 cells, 35.2 kg, 210 welds.
- LFP prismatic 280 Ah, 896 Wh: 6 cells, 32.4 kg, 12 bolted connections.
Six cells against three hundred and ninety-seven. That is the real subject of this article, and it appears on no datasheet.
Why the weld count decides everything
Every weld is a possible failure point. A poorly made spot weld holds mechanically but shows a higher resistance: it heats, oxidises, resists more, heats more. It is a spiral, and a slow one, so nobody sees it coming.
On a pack with 794 welds, one bad weld in a hundred means eight of them. On a prismatic pack with 12 bolted connections, a loose connection shows up as torque and is fixed with a torque wrench.
That is the main reason we steer every stationary pack towards prismatic, and not an aesthetic preference. Cylindrical keeps its place where volume or shape demands it.
A cylindrical pack is not built with pliers and solder. Solder heats the cell far longer than a spot weld and damages the electrolyte near the pole. If someone offers you a soldered pack, ask to see the contact point.
What each format genuinely does well
No format is better in the abstract. Each has a domain where it has no competitor.
- 18650: availability and shape. It is the most widespread format in the world, and the only one that fits certain tool or bicycle housings. When the space has an imposed shape, this is the one.
- 21700: the best cylindrical compromise. A third more volume than an 18650 for forty per cent more energy, so fewer cells to build for the same energy.
- 32700: the small LFP pack format. When you want LFP cycle life in a modest volume without moving to prismatic, this is the entry point.
- 32140: the large cylindrical. Two and a half times the energy of a 32700, so far fewer welds per kilowatt-hour. Useful when prismatic does not fit.
- Prismatic: stationary work. Six cells, twelve bolts, a pack that comes apart and cells replaceable one at a time.
Energy per kilogram, and why it misleads
The table gives 263 Wh/kg for the 18650 NMC and 132 Wh/kg for the 32700 LFP: NMC looks twice as good. For a fixed pack, that ratio means nothing.
A solar kit battery is not carried. What counts is cycles per installed kilowatt-hour, and there LFP returns five times more. Energy per kilogram only has value on things that move: a zem, a bicycle, a hand tool.
Conversely, on a two-wheeler, 19 kg against 38 kg for the same energy is a difference the rider feels in every corner.
There is a third quantity nobody talks about, and it decides the price of a finished pack: energy per weld. The 18650 gives 6.3 Wh per weld, the 280 Ah prismatic gives 448. That is a factor of seventy on workshop time, and workshop time is paid for.
Mixing two formats in one pack: no
The question comes up as soon as cells are left over from an earlier build. The answer is no, and for a reason that is not arbitrary.
Two formats share neither internal resistance, nor capacity, nor the way they take current. Wired in parallel they do not split the current evenly: the least resistant cell takes the largest share, heats more, ages faster, and the gap widens on its own.
The same rule, stricter still, applies to cells of the same format but different batches, or different ages. A pack is built from cells matched on capacity and internal resistance, full stop. Leftover cells serve something else: a small separate pack, a light, a prototype.
If you have a mixed batch in hand, sort it by measured capacity and build several small homogeneous packs rather than one lopsided large one. You will lose elegance and gain years.
How we choose, in practice
Three questions are enough, and they come in this order.
- Does the pack move? If not, prismatic, unless the space has an impossible shape.
- Does the space have an imposed shape? A long narrow housing calls for cylindrical; a rectangular box accepts prismatic.
- How many cycles a year? Past three hundred, LFP wins, whatever the format.
You will notice chemistry comes after geometry. That is deliberate: you can nearly always find the chemistry you want in a given format, whereas you cannot fit a prismatic cell into a bicycle frame.
Give us the internal dimensions of the space before the capacity you want. A pack that does not fit is a pack to rebuild, and rebuilding means unsoldering.